Audi Q7 Owners & Service Manuals

Audi Q7: Battery Charger -VAS5900-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

The charge current for the Battery Charger -VAS5900- can be read directly on the Battery Charger -VAS5900-.

  Note

Observe the Battery Charger -VAS5900- Operating Instructions.

  • Battery Charger -VAS5900- device description. Refer to → Chapter "Battery Charger -VAS5900- Device Description".
  • Charge the Battery -A-. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5900-".
  • Service charge. Refer to → Chapter "Battery Charger -VAS5900- Service Charge".
  • Severely discharged Battery -A-, charging. Refer to → Chapter "Severely Discharged Battery, Charging with Battery Charger -VAS5900-".
  • Support mode. Refer to → Chapter "Battery Charger -VAS5900- Support Mode".
  • Maintenance charging. Refer to → Chapter "Battery Charger -VAS5900- Maintenance Charging".

Battery Charger -VAS5900- Device Description

The Battery Charger -VAS5900- is designed to charge all 12 V Batteries -A- in the VW group.

Battery Charger -VAS5900-

W00-10182

Control Field Overview

N27-10168

1 - Display

2 - ↑-button "Up"

3 - ↓-button "Down"

4 - START/STOP-button

5 - INFO-button

Battery, Charging with Battery Charger -VAS5900-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required

  • Battery Charger -VAS5900-

  Note

The Battery -A- temperature must be at least 10 ºC.

Procedure

- Turn off the ignition and all electrical consumers and remove the ignition key.

- Connect the Battery Charger -VAS5900- to the power supply. The last selected mode is shown on the display. Refer to → Chapter "Battery Charger -VAS5900- Device Description".

- Set the battery type with the INFO button.

The symbol -1- for "standard charge of wet batteries" or the symbol -2- for "standard charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑ button or ↓ button.

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

N27-10169

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

The Battery Charger -VAS5900- recognizes the nominal voltage of the connected Battery -A- (6 V/12 V/24 V) and begins the charging process automatically.

The Battery Charger -VAS5900- begins the "final charging" when the charge level is approximately 80 to 85%. The fourth bar is indicated on the display -1-. The Battery -A- is ready to be used.

N27-10170

With a charge status of 100%, all bars are indicated on the display -1-.

  Note

  • With the "standard charge", parallel operation of electrical consumers during the charging process is possible. The charging time is lengthened by this.
  • Depending on the battery type, the Battery Charger -VAS5900- switches to maintenance charging after 1 to 7 hours. To reach a 100% charge level, the Battery -A- should remain connected to the Battery Charger -VAS5900-.

N27-10180

Possible malfunctions and how they are handled

1 - Displayed voltage does not match the nominal voltage:

- Hold down the ↑ button or ↓ button until the charging process begins.

2 - Displayed battery voltage does not match the nominal voltage - the charging process has already begun:

- Press the START/STOP button two times.

- Hold down the ↑ button or ↓ button until the charging process begins again.

3 - The Battery Charger -VAS5900- does not recognize the Battery -A-, if the battery voltage is less than 2V:

The display remains unchanged.

The selected battery type and Ampere hours (Ah) are displayed.

Battery -A- charging, ending

- Press the START/STOP-button.

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5900- from the power.

Battery Charger -VAS5900- Service Charge

   WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  Caution

"Service charging" is not permitted for VW vehicles, because voltage surges can damage the on-board electronics.

The Battery -A- must always be disconnected from the vehicle electrical system when using the "service charge" mode.

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

  Caution

Always set the mode that corresponds to the Battery -A- during the charging process. Refer to the Battery Charger -VAS5900- Operating Instructions.

"Service Charging" is suitable for:

Wet batteries having a visual indicator which allows charging (visual indicator black or green).

The "Service charge (SERV)" mode is only used with sulfated Batteries -A-. The Battery -A- with voltages greater than 14.4 V is charged. A partial removal of the sulfation layer can result from this. Check the visual indicator after charging, immediately before the Battery -A- is used. Refer to → Chapter "Visual Indicator Color Display, Checking".

Special tools and workshop equipment required

  • Battery Charger -VAS5900-

  Note

The Battery -A- temperature must be at least 10 ºC (50 ºF).

Procedure

- Turn off the ignition and all electrical consumers and remove the ignition key.

- Connect the Battery Charger -VAS5900- to the power supply. The last selected mode is shown on the display. Refer to → Chapter "Battery Charger -VAS5900- Device Description".

- Set the battery type with the INFO button.

The symbol -1- for "service charge of wet batteries" or the symbol -2- for "service charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑ button or ↓ button.

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

N27-10179

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

The Battery Charger -VAS5900- recognizes the nominal voltage of the connected Battery -A- (6 V/12 V/24 V) and begins the charging process automatically.

The Battery Charger -VAS5900- begins the "final charging" when the charge level is approximately 80 to 85 % of the battery voltage. The fourth bar is indicated on the display -1-. The Battery -A- is now ready to be used.

N27-10170

  Note

A successful "service charge" depends on the degree of sulfation on the Battery -A-.

Possible malfunctions and how they are handled

1 - Displayed voltage does not match the nominal voltage:

- Hold down the ↑ button or ↓ button until the charging process begins.

2 - Displayed battery voltage does not match the nominal voltage - the charging process has already begun:

- Press the START/STOP button two times.

- Hold down the ↑ button or ↓ button until the charging process begins.

3 - The charger does not recognize a Battery -A-, when the battery voltage is less than 2 V:

The display remains unchanged.

The set operating mode and Ampere-hours (Ah) are displayed.

Battery -A- charging, ending

- Press the START/STOP-button.

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5900- from the power.

Severely Discharged Battery, Charging with Battery Charger -VAS5900-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

  Caution

  • The polarity protection of the charger clamps is not active in the operation mode "charging severely discharged batteries/Support mode". Connect the charger clamps to the battery terminals correctly according to polarity!
  • Always set the mode that corresponds to the Battery -A- during the charging process. Refer to the Battery Charger -VAS5900- Operating Instructions.
  • The Battery Charger -VAS5900- does not recognize the severely discharged Battery -A-. Refer to → Chapter "Severely Discharged Batteries".
  • Do not touch START / STOP button when battery cables are incorrectly connected! The Battery Charger -VAS5900- can become damaged.

The Battery Charger -VAS5900- will not automatically recognize the Battery -A- for Batteries -A- with a voltage less than 2 V.

Special tools and workshop equipment required

  • Battery Charger -VAS5900-

  Note

  • For information in the chapter. Refer to → Chapter "Severely Discharged Batteries".
  • The Battery -A- temperature must be at least 10 ºC (50 ºF).
  • Severely discharged batteries in vehicles must be replaced prior to delivery. Pre-existing damage cannot be ruled out.

Procedure

- Turn off the ignition and all electrical consumers and remove the ignition key.

- Connect the Battery Charger -VAS5900- to the power supply. The last selected mode is shown on the display. Refer to → Chapter "Battery Charger -VAS5900- Device Description".

- Set the battery type with the INFO button.

The symbol -1- for "service charge of wet batteries" or the symbol -2- for "service charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑ button or ↓ button.

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

N27-10169

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

- Press the START/STOP button for about 5 seconds. The menu selection "Charging severely discharged batteries/Support mode" is activated.

- Press the corresponding ↑-button or ↓ button to adjust the battery voltage(6 V/12 V/24 V).

  Note

If no button is touched within five seconds, the Battery Charger -VAS5900- will return to the main menu (operating mode selection).

- Select the battery voltage by pressing the START/STOP button.

Then the inquiry about the correct polarity of the charging clamps is made.

- Check correct polarity connection of charger clamps.

- Confirm charging clamps are connected to correct poles via START/STOP button.

The Battery Charger -VAS5900- starts to charge the severely discharged Battery -A-.

Battery -A- charging, ending

- Press the START/STOP-button.

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5900- from the power.

Battery Charger -VAS5900- Support Mode

General Information

The support mode provides the vehicle electrical system with voltage when the Battery -A- is removed or disconnected.

For more information. Refer to the Battery Charger -VAS5900- Operating Instructions.

The support mode is used for the following situations:

  • Vehicle electrical system support mode with the Battery -A- not installed
  • Maintaining the voltage when the battery is being replaced
  • Systems test without the Battery -A-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required

  • Battery Charger -VAS5900-

Procedure

  Caution

  • The polarity protection of the charger clamps is not active in the operation mode "charging severely discharged batteries/Support mode". Connect the charger clamps to the battery terminals correctly according to polarity!
  • It can result in sparks due to short circuit.
  • This constitutes an explosion risk.
  • Do not touch START / STOP button when battery cables are incorrectly connected! The Battery Charger -VAS5900- can become damaged.

- Remove the Battery -A-. Refer to → Electrical Equipment; Rep. Gr.27; Battery; Battery, Removing and Installing.

- Connect the Battery Charger -VAS5900- to the power supply. The last selected mode is shown on the display. Refer to → Chapter "Battery Charger -VAS5900- Device Description".

  Caution

Whenever the Battery -A- is removed, be careful to prevent contact between the connected charge clamp on the positive terminal and the body ground. Likewise prevent contact between the battery terminals.

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

- Press the START/STOP button for about 5 seconds. The menu selection "Charging severely discharged batteries/Support mode" is activated.

- Press the corresponding ↑-button or ↓ button to adjust the battery voltage(6 V/12 V/24 V).

  Note

If no button is touched within five seconds, the Battery Charger -VAS5900- will return to the main menu (operating mode selection).

- Select the battery voltage by pressing the START/STOP button.

Then the inquiry about the correct polarity of the charging clamps is made.

- Check correct polarity connection of charger clamps.

- Confirm charging clamps are connected to correct poles via START/STOP button.

The Battery Charger -VAS5900- starts the Battery -A- support mode.

End the Battery Support Mode

- Press the START/STOP-button.

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5900- from the power.

Battery Charger -VAS5900- Maintenance Charging

  Note

  • If the Battery -A- is discharged by an electrical consumer during maintenance charging, the Battery Charger -VAS5900- automatically supplies the appropriate charge.
  • Maintenance charging can be performed without time restrictions.
  • The Battery -A- can be used constantly.
  • Observe the maintenance notes of the battery manufacturer.

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

If the Battery -A- is fully charged, the Battery Charger -VAS5900- starts maintenance charging.

Special tools and workshop equipment required

  • Battery Charger -VAS5900-

Procedure

- Proceed as if charging the Battery -A-. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5900-".

With a charge status of 100%, all bars are indicated on the display -1-.

N27-10180

    READ NEXT:

     Battery Charger -VAS5903-

      WARNING Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".   WARNING Do not check or charge a Battery -A

     Battery Charger -VAS5906-

      WARNING Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".   WARNING Do not check or charge a Battery -A

     Solar Battery Maintainer -VAS6102A-

    Solar Battery Maintainer -VAS6102A- Device Description Solar Battery Maintainer -VAS6102A- The Solar Battery Maintainer -VAS6102A- supports the vehicle electrical system and prevents the Battery -A-

    SEE MORE:

     Rear Expansion Valve, Removing and Installing

      Caution This procedure contains mandatory replaceable parts. Refer to component overview prior to starting procedure. Mandatory Replacement Parts O-ring - Rear Expansion Valve to Refrigerant Line - High Pressure Side O-ring - Refrigerant Line - Low Pressure Side to Rear Expansion Valv

     Test Sequence

    Battery, Checking, Vehicles with Battery Monitoring Control Module J367 or Energy Management Control Module J644 and Data Bus On Board Diagnostic Interface J533 In certain model series the following is responsible for monitoring the electrical system: Energy Management Control Module -J644- or

    © 2019-2024 Copyright www.a-q7.com